MPW WAITLIMIT: Difference between revisions
Jump to navigation
Jump to search
Created page with "'''MPW_WAITLIMIT''' is a dynamic system parameter that sets the number of pages on the modified-page list that causes a process to wait until the next ti..." |
mNo edit summary |
||
| Line 1: | Line 1: | ||
'''MPW_WAITLIMIT''' is a dynamic [[System Parameters|system parameter]] that sets the number of pages on the modified-page list that causes a process to wait until the next time the modified- page writer writes the modified list. This parameter limits the rate at which any single process can produce modified pages. If this value is less than MPW_HILIMIT, a system deadlock occurs. The value for this parameter is normally equal to | '''MPW_WAITLIMIT''' is a dynamic [[System Parameters|system parameter]] that sets the number of pages on the modified-page list that causes a process to wait until the next time the modified- page writer writes the modified list. This parameter limits the rate at which any single process can produce modified pages. If this value is less than MPW_HILIMIT, a system deadlock occurs. The value for this parameter is normally equal to [[MPW_HILIMIT]]. | ||
MPW_WAITLIMIT has the AUTOGEN and DYNAMIC attributes. | MPW_WAITLIMIT has the AUTOGEN and DYNAMIC attributes. | ||
[[Category:System Parameters]] | [[Category:System Parameters]] | ||
Latest revision as of 20:56, 28 October 2019
MPW_WAITLIMIT is a dynamic system parameter that sets the number of pages on the modified-page list that causes a process to wait until the next time the modified- page writer writes the modified list. This parameter limits the rate at which any single process can produce modified pages. If this value is less than MPW_HILIMIT, a system deadlock occurs. The value for this parameter is normally equal to MPW_HILIMIT.
MPW_WAITLIMIT has the AUTOGEN and DYNAMIC attributes.