Search results

Jump to: navigation, search
  • ... typical work loads, and adjust the values of system parameters as needed. Each system parameter has associated minimum and maximum values that define ...
    2 KB (327 words) - 12:42, 8 April 2019
  • '''JOB parameters''' are system parameters for job control. class="wikitable" - Name Attributes Description Default Min Max ...
    512 bytes (78 words) - 10:05, 18 December 2018
  • '''LGI parameters''' are system parameters that control login security. class="wikitable" - Name Attributes Description Default Min ...
    4 KB (639 words) - 04:18, 23 August 2018
  • ... To disable the feature, set ACP_WRITEBACK to 0. This system parameter affects only applications like PATHWORKS that can request deferred writes ...
    7 KB (1,120 words) - 04:01, 23 August 2018
  • ... recording some trace information. Enabling SYSTEM_CHECK causes the system to behave as if the following system parameter values are set (although the ...
    2 KB (220 words) - 08:41, 2 July 2019
  • ... SYSUAF database only the first time a system password is set up on the ... 19 (hexadecimal value 80000) in the parameter TTY_DEFCHAR2. Note that if you ...
    4 KB (600 words) - 11:51, 18 January 2019
  • '''WINDOW_SYSTEM''' is a System Parameters system parameter that specifies the windowing system to be used on a workstation. =Values= class=" ...
    411 bytes (52 words) - 09:34, 2 July 2019
  • ... CLI symbol table. The size of this table is defined in the system parameter CLISYMTBL . In any process, CLI defines the following reserved symbols ...
    5 KB (718 words) - 08:05, 2 December 2019
  • ... OpenVMS Cluster systems. The node name is specified by the system parameter SCSNODE for the processor on which the queue executes. For ...
    16 KB (2,584 words) - 06:39, 4 September 2018
  • '''AFFINITY_SKIP''' is a system parameter that controls the breaking of implicit affinity. The value inficates the number of times a process is ...
    326 bytes (53 words) - 12:37, 8 April 2019
  • ... that is between the values of the FREELIM and FREEGOAL system parameters usually indicates deficient memory and is often accompanied by a high ...
    1,000 bytes (152 words) - 06:10, 3 July 2019
  • ... process that have been modified. It is controlled with the MPW system parameters: MPW_HILIMIT sets the upper limit for the modified page list. ...
    1 KB (194 words) - 06:20, 3 July 2019
  • ... by the quotas of the creator process (maximum) and the system parameters PQL_M (minimum). The DETACH or CMKRNL privilege allows you to ...
    2 KB (291 words) - 08:22, 10 July 2019
  • ... node allocation class. OpenVMS Version 7.2 introduced the MSCP_SERVE_ALL system parameter, which can be set to serve all disks or to exclude ...
    1 KB (199 words) - 18:25, 13 December 2019
  • ... running system. Also starting with OpenVMS Version 8.3 , the NISCS_PORT_SERV system parameter is dynamic, that is, changing the setting of this ...
    1 KB (188 words) - 13:01, 8 November 2019
  • ... , VSI does not recommend altering the setting of the system parameter PHYSICAL_MEMORY from its default setting of -1. Artificially reducing the amount ...
    901 bytes (135 words) - 14:53, 29 June 2019
  • ... enforced. SYSBOOT truncates the value of SCSNODE if the size of the system parameter is set to more than six characters. If the computer is in ...
    709 bytes (118 words) - 15:20, 1 July 2019
  • ... on this device. See the MVSUPMSG_INTVL and MVSUPMSG_NUM system parameters for more information on the suppression of mount verification ...
    37 KB (5,607 words) - 11:27, 28 October 2022
  • ... SYS$SYSTEM and is invoked with RUN or MCR. =Uses= system parameter modification managing devices and device drivers (taken over by SYSMAN ...
    1 KB (207 words) - 18:58, 12 December 2019
  • ... must be present for the Cluster cluster to function. =System Parameters= Two system parameters, VOTES and EXPECTED_VOTES , are key to the ...
    4 KB (589 words) - 15:39, 17 August 2021

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)