Search results

Jump to: navigation, search
  • ... typical work loads, and adjust the values of system parameters as needed. Each system parameter has associated minimum and maximum values that define ...
    2 KB (327 words) - 12:42, 8 April 2019
  • '''JOB parameters''' are system parameters for job control. class="wikitable" - Name Attributes Description Default Min Max ...
    512 bytes (78 words) - 10:05, 18 December 2018
  • '''LGI parameters''' are system parameters that control login security. class="wikitable" - Name Attributes Description Default Min ...
    4 KB (639 words) - 04:18, 23 August 2018
  • ... To disable the feature, set ACP_WRITEBACK to 0. This system parameter affects only applications like PATHWORKS that can request deferred writes ...
    7 KB (1,120 words) - 04:01, 23 August 2018
  • ... recording some trace information. Enabling SYSTEM_CHECK causes the system to behave as if the following system parameter values are set (although the ...
    2 KB (220 words) - 08:41, 2 July 2019
  • ... SYSUAF database only the first time a system password is set up on the ... 19 (hexadecimal value 80000) in the parameter TTY_DEFCHAR2. Note that if you ...
    4 KB (600 words) - 11:51, 18 January 2019
  • '''WINDOW_SYSTEM''' is a System Parameters system parameter that specifies the windowing system to be used on a workstation. =Values= class=" ...
    411 bytes (52 words) - 09:34, 2 July 2019
  • ... CLI symbol table. The size of this table is defined in the system parameter CLISYMTBL . In any process, CLI defines the following reserved symbols ...
    5 KB (718 words) - 08:05, 2 December 2019
  • ... OpenVMS Cluster systems. The node name is specified by the system parameter SCSNODE for the processor on which the queue executes. For ...
    16 KB (2,584 words) - 06:39, 4 September 2018
  • '''AFFINITY_SKIP''' is a system parameter that controls the breaking of implicit affinity. The value inficates the number of times a process is ...
    326 bytes (53 words) - 12:37, 8 April 2019
  • ... that is between the values of the FREELIM and FREEGOAL system parameters usually indicates deficient memory and is often accompanied by a high ...
    1,000 bytes (152 words) - 06:10, 3 July 2019
  • ... process that have been modified. It is controlled with the MPW system parameters: MPW_HILIMIT sets the upper limit for the modified page list. ...
    1 KB (194 words) - 06:20, 3 July 2019
  • ... by the quotas of the creator process (maximum) and the system parameters PQL_M (minimum). The DETACH or CMKRNL privilege allows you to ...
    2 KB (291 words) - 08:22, 10 July 2019
  • ... node allocation class. OpenVMS Version 7.2 introduced the MSCP_SERVE_ALL system parameter, which can be set to serve all disks or to exclude ...
    1 KB (199 words) - 18:25, 13 December 2019
  • ... running system. Also starting with OpenVMS Version 8.3 , the NISCS_PORT_SERV system parameter is dynamic, that is, changing the setting of this ...
    1 KB (188 words) - 13:01, 8 November 2019
  • ... , VSI does not recommend altering the setting of the system parameter PHYSICAL_MEMORY from its default setting of -1. Artificially reducing the amount ...
    901 bytes (135 words) - 14:53, 29 June 2019
  • ... enforced. SYSBOOT truncates the value of SCSNODE if the size of the system parameter is set to more than six characters. If the computer is in ...
    709 bytes (118 words) - 15:20, 1 July 2019
  • ... on this device. See the MVSUPMSG_INTVL and MVSUPMSG_NUM system parameters for more information on the suppression of mount verification ...
    37 KB (5,607 words) - 11:27, 28 October 2022
  • ... SYS$SYSTEM and is invoked with RUN or MCR. =Uses= system parameter modification managing devices and device drivers (taken over by SYSMAN ...
    1 KB (207 words) - 18:58, 12 December 2019
  • ... must be present for the Cluster cluster to function. =System Parameters= Two system parameters, VOTES and EXPECTED_VOTES , are key to the ...
    4 KB (589 words) - 15:39, 17 August 2021
  • ... You can set this system parameter with the DCL command SET RMS_DEFAULT/SYSTEM/CONTENTION_POLICY=value and display the parameter with the DCL command ...
    1 KB (155 words) - 06:27, 30 June 2019
  • ... each I/O buffer. You can set this system parameter with the DCL command SET RMS_ DEFAULT/SYSTEM and display the parameter with the SHOW RMS_ DEFAULT ...
    426 bytes (70 words) - 16:26, 30 June 2019
  • ... relative file. You can set this system parameter with the DCL command SET RMS_DEFAULT/SYSTEM and display the parameter with SHOW RMS_ DEFAULT. RMS ...
    441 bytes (68 words) - 16:27, 30 June 2019
  • ... performance. You can set this system parameter with the DCL command SET RMS_DEFAULT/SYSTEM and display the parameter with SHOW RMS_ DEFAULT. RMS ...
    583 bytes (87 words) - 16:27, 30 June 2019
  • ... tape files. You can set this system parameter with the DCL command SET RMS_DEFAULT/SYSTEM and display the parameter with SHOW RMS_ DEFAULT. RMS ...
    442 bytes (68 words) - 16:27, 30 June 2019
  • ... record devices. You can set this system parameter with the DCL command SET RMS_DEFAULT/SYSTEM and display the parameter with SHOW RMS_ DEFAULT. RMS ...
    344 bytes (51 words) - 16:27, 30 June 2019
  • ... by 512 bytes. You can set this system parameter with the DCL command SET RMS_DEFAULT/SYSTEM and display the parameter with SHOW RMS_DEFAULT. RMS_DFNBC ...
    1 KB (178 words) - 16:30, 30 June 2019
  • ... it closes. You can set this system parameter with the DCL command SET RMS_DEFAULT/SYSTEM and display the parameter with SHOW RMS_DEFAULT. RMS_EXTEND ...
    794 bytes (133 words) - 16:30, 30 June 2019
  • ... performance. You can set this system parameter with the DCL command SET RMS_DEFAULT/SYSTEM and display the parameter with SHOW RMS_DEFAULT. RMS ...
    571 bytes (89 words) - 16:52, 30 June 2019
  • ... _MAX_UNIT. On Alpha and Integrity servers, the default value for this system parameter is 500, which consumes 24 KB of main memory. If you do ...
    1 KB (239 words) - 15:05, 2 July 2019
  • ... for OpenVMS for more information about setting system parameters for volume shadowing. This parameter is available for Phase II Shadowing only. ...
    612 bytes (96 words) - 15:12, 2 July 2019
  • ... OpenVMS Cluster systems. The node name is specified by the system parameter SCSNODE for the processor on which the queue executes. - ENTRY ...
    33 KB (5,271 words) - 09:44, 13 September 2018
  • ... to set the new system parameters in the default parameter file, saves the original parameters, and generates a new parameter file, AUTOGEN.PAR. On VAX ...
    3 KB (499 words) - 09:18, 2 July 2019
  • ... that is between the values of the FREELIM and FREEGOAL system parameters usually indicates deficient memory and is often accompanied by a high ...
    3 KB (473 words) - 05:38, 3 July 2019
  • ... is used on subsequent reboots. The file is not created if the system parameter STARTUP_P1 is set to MIN =See also= Template:Cluster Category ...
    445 bytes (73 words) - 09:19, 7 April 2019
  • ... out of internal SHM_REG data structures. You need to increase the system parameter GLX_SHM_REG and reboot all Galaxy instances with this larger ...
    666 bytes (105 words) - 06:36, 9 April 2019
  • ... Performs Standard Time and Daylight Saving Time clock adjustments, when the system parameter AUTO_DLIGHT_SAV is 1. As a known, persistent process JOB ...
    1 KB (227 words) - 14:00, 2 June 2020
  • ... doing so, however, it is a good idea to make sure that the system parameters will allow the settings chosen for the Tomcat user account. The table ...
    49 KB (7,079 words) - 07:13, 20 October 2021
  • ... ( ), the queue manager will not be moved. Note System Parameter JOBCTLD If the system parameter JOBCTLD low bit is set, the job controller ...
    8 KB (1,345 words) - 17:56, 20 May 2020
  • ... requirements must be met for the operating system to write a useful system dump file: The system parameter DUMPBUG must be set to 1 (the default ...
    6 KB (1,127 words) - 13:54, 12 November 2019
  • ... is equal to or less than the value specified by the system parameter DEFPRI default=4 .) After SUSP (suspended) processes, DORMANT processes are ...
    818 bytes (122 words) - 05:31, 9 April 2019
  • ... parameter. FAST_PATH_PORTS is relevant only if the FAST_PATH system parameter is enabled (equal to 1). Setting FAST_PATH to zero has the same ...
    2 KB (279 words) - 06:07, 9 April 2019
  • ... , they may not be set lower than the following system parameters: PQL_MSDEFAULT PQL_MWSQUOTA PQL_MWSEXTENT Subprocesses and detached ...
    3 KB (498 words) - 05:59, 3 July 2019
  • ... off pool reclamation but keep both NPAG_AGGRESSIVE and NPAG_GENTLE system parameters set to 100. NPAG_AGGRESSIVE is a DYNAMIC parameter. Category ...
    1 KB (210 words) - 11:39, 29 June 2019
  • ... turn off pool reclamation but keep both NPAG_AGGRESSIVE and NPAG_GENTLE system parameters set to 100. NPAG_GENTLE is a DYNAMIC parameter. Category ...
    1 KB (209 words) - 13:53, 29 June 2019
  • ... by selecting the highest number from all of the following: each node's system parameter EXPECTED_VOTES, the sum of the votes currently in the cluster ...
    54 KB (8,797 words) - 19:32, 13 November 2019
  • ... is a hard limit on all versions of OpenVMS. The value of the VIRTUALPAGECNT system parameter limits the total size of the sum of P0 space and P1 ...
    122 KB (18,338 words) - 07:03, 23 December 2019
  • ... /Tomcat_(CSWS_JAVA)_-_Easy_Installation_Guide Setting_System_Parameters Tomcat - Easy Installation Guide for detailed instructions ...
    50 KB (7,396 words) - 17:34, 26 January 2022
  • ... Services :Category:Privileges Privileges :Category:System Parameters System Parameters :Category:Utilities Utilities :Category ...
    7 KB (921 words) - 13:44, 15 November 2023
  • ... 's output buffer, which cannot be larger than the value of the system parameter MAXBUF . If the buffer is very small, the symbiont might need ...
    8 KB (1,326 words) - 09:41, 9 April 2019

View (previous 50 | next 50) (20 | 50 | 100 | 250 | 500)